H3 Water pump forced circulating coolant heaters are installed at the lowest point in a system, the coolant can be warmed up quickly and delivered to the top of engine by the thermosphere, so as to reduce the time to reach operating temperatures and full-load acceptance. It will be great  for use in power generation, diesel gensets, Gas gensets, industrial engines, trucks, etc.

  • Volts :

    230/115V
  • Regulating Thermostart :

    35-50℃(95-122°F)
  • Watt :

    2000,2500, 3000, 4000W
  • Inlet/Outlet Diameter :

    3/4“(19mm)
  • Hz :

    50/60Hz
  • MOQ Order :

    50PCS

Topstart H3 Water Pump Forced Circulation Heater for Power Generation

 

The Topstart H3 Series Water Pump Forced Circulation Heater is a compact heating system with a circulation pump that heats the coolant liquid of a motor. This system is particularly made for generating sets, on-road engines, marine engines, and all types of vehicles located inside or outside (protected place only). The output could be from 2; 2.5,3,4.0 kW with customization by 230 or 115V AC.

 

Product Features:

Heating Unit

·Die-cast aluminum housing

· PA66 electrical covers and support base

· Available with 1.5m power cord

· Heating element made of  incoloy 800H

·Integrated mounting holes

 

Circulating Pump

·Circulation centrifugal pump

·Flow rate:2M/h 

·Lit head:3m

 

Safety Thermostat

 

.110℃ Safety thermostat with

. manual reset rated at 25A to protect

. the heating element when coolant

 

Regulating Thermostat

.35-50°C (95-122°F)

 

Available Power

· 2.0 to 4KW

·120,230,240V ·50 or 60Hz

 

Topstart H3 Water Pump Forced Circulation Heater Heating System for Power Generation

 

Technical Data:

Model

Hz

Volts

Phase

Watt

Regulating Thermostat

Safety Thermostat

Cord Length

Plug Type

Inlet/Outlet Diameter

QZ 2000R

50/60

230/115

1

2000

35-50℃

110℃

1.5M

Blunt 3 Wire

3/4"(19mm)

QZ 2500R

50/60

230/115

1

2500

35-50℃

110℃

1.5M

Blunt 3 Wire

3/4"(19mm)

QZ 3000R

50/60

230/115

1

3000

35-50℃

110℃

1.5M

Blunt 3 Wire

3/4"(19mm)

QZ 4000R

50/60

230/115

1

4000

35-50℃

110℃

1.5M

Blunt 3 Wire

3/4"(19mm)

 

Benefits:

·The Topstart water pump forced circulation heater provides engine warming for a quick, clean start

·Reduce time to reach operating temperatures

· Even distribution of heat to eliminate cold spots

· Reduce engine wear stress on hoses & fittings

 

Applications:

· Diesel Gensets

· Gas Gensets

. Industrial Engine Applications

. Truck or other vehicles

 

Heater Assembly:

assembly of H3 Topstart water pump forced circulation heaters

1. Circulating water pump

2. Overheat safety thermostat

3. Regulating thermostat

4. Fixingbracket

5. Support base

6. Electric box

7. Heating element

8. Casting aluminum tank

9. Thermal insulation material

Each thermostat will be tested before shipment and has a quality warranty of 2 years.

 

Installation Diagram and Dimension:

installation diagram and dimension for Topstart H3 Series Water Pump Forced Circulation Heater

 

Products With Mounting Kit and Accessories:

Each pump will come with one set of mounting kits and a 3/4" NPT or BSP outlet

delivered with mounting kit and outlet for topstart heater

горячие теги : Water Pump Forced Circulation Heater
оставить сообщение
Если вы заинтересованы в наших продуктах и хотите узнать больше деталей, пожалуйста, оставьте сообщение здесь, мы ответим вам, как только сможем.
сопутствующие товары
  • Flowstart V1 Self-Circulation Pre-heating System Self-Circulating Coolant Heater
    Custom Flowstart V1 Electric Coolant Heater Self-Circulation

    H3 Water pump forced circulating coolant heaters are installed at the lowest point in a system, the coolant can be warmed up quickly and delivered to the top of engine by the thermosphere, so as to reduce the time to reach operating temperatures and full-load acceptance. It will be great  for use in power generation, diesel gensets, Gas gensets, industrial engines, trucks, etc.

  • Thermostart H2 Self-Circulation Engine Heater Without Pump Electric Coolant Preheater
    Thermostart H2 Self-Circulation Engine Heater without Pump

    H3 Water pump forced circulating coolant heaters are installed at the lowest point in a system, the coolant can be warmed up quickly and delivered to the top of engine by the thermosphere, so as to reduce the time to reach operating temperatures and full-load acceptance. It will be great  for use in power generation, diesel gensets, Gas gensets, industrial engines, trucks, etc.

  • Topstart H3 Water Pump Forced Circulation Heater Heating System for Power Generation
    Topstart H3 Water Pump Forced Circulation Heater for Power Generation

    H3 Water pump forced circulating coolant heaters are installed at the lowest point in a system, the coolant can be warmed up quickly and delivered to the top of engine by the thermosphere, so as to reduce the time to reach operating temperatures and full-load acceptance. It will be great  for use in power generation, diesel gensets, Gas gensets, industrial engines, trucks, etc.

оставить сообщение
оставить сообщение
Если вы заинтересованы в наших продуктах и хотите узнать больше деталей, пожалуйста, оставьте сообщение здесь, мы ответим вам, как только сможем.

Дом

Товары

whatsApp